  • Variable Power Supply

    VS3 - Allied Edison LLC

    The VS-3 power supply is a very convenient portable, non-isolated “variable source” from 0 volts to 150 Vac or 0 volts to 150 Vdc and rated for up to 3 amps, thus the name VS-3. It is comprised of an illuminated voltmeter that reads to the first significant digit, AC variable system output voltage, DC variable system output voltage, logic output voltage and one sense (continuity) contact monitoring points. Banana jacks for connection of test leads are spaced at intervals that allow the use of dual banana test plugs if desired. The VS-3 is protected by two levels of overcurrent protection; AC input, and ground fault protection by a GFCI. All circuitry is housed inside a custom designed case made from 16 gauge steel. An Internal fan dissipates heat buildup and exhaust through louvered side vents built into the case. The carrying handle is designed with a “spring return to rest” position and is padded for comfort. The case has been sized for optimum portability and is balanced from the handle during transportation. The case has a powder coated finish that is scratch, chemical and weather resistant. Rubber padded feet support the case when in the upright position and a convenience receptacle is located on the side of the case. A unique feature of the VS-3 is that it contains “Magnet Packs” on the back of the case. These “Magnet Packs” can support the VS-3 and allow it to “hang” from any magnetic metal surface. The VS-3 can be powered by our UPS system, eliminating the need for an extension cord. The ability to magnetically attach the VS-3 near the source of connection and eliminating the need for an extension cord makes the VS-3 a “must have tool” for technicians.

  • High Voltage, Continuity & Hipot, Cable & Wire Harness Test Systems

    CableEye HVX, HVX-21 - CAMI Research Inc. (CableEye®)

    Fast ● Simple ● Precise Advanced wiring analyzer scans for continuity (opens, shorts), miswires, resistance, capacitance, components (resistors, diodes, LEDs, capacitors) dielectric breakdown, insulation resistance, intermittent connections HVX (Item 829) 1500 Vdc, 1000 Vac HVX-21 (Item 829A) 2100 Vdc, 1200 Vac For diagnostic and Pass/Fail Testing — Permits expanded testing (compared to models in our low voltage product line) for insulation resistance (IRI) and dielectric breakdown (DWV). All CableEye testers are suitable for production, fault diagnosis, QC (Quality Control), assembly, and prototyping of standard or custom cables. Each combines test, fault location, design, documentation, labeling, and database storage in one instrument. Tests can be performed on long cables (with or without connectors) or no cables (e.g. connectors, backplanes, PCBs, components). Standard Features & Benefits:

    • USB certified, PC-based tester for a versatile, fast, robust system with long life-cycle.
    • Multilingual, dynamic, graphic-rich display (netlist & wiring schematic) provides clarity and speeds diagnostics.
    • 128 Test Points, expandable to 1024 providing flexibility as your product line changes.
    • User-selectable voltage to each connection group in the cable simplifies an otherwise complex process, accelerating testing.
    • Programmable Ramp Up, Ramp Down, Dwell Time (same as Test Time), Trip Current, and Trip Delay (same as Soak Time) adds versatility.
    • Current leakage detected during HV test phase provides a measure of insulation resistance up to 1 GΩ (HVX) and 5 GΩ (HVX-21) - any leakage current exceeding a preset limit reveals the presence of moisture, flux, or other contamination on exposed contacts.
    • Real-time screening for intermittent connections for pinpointing elusive faults and improving quality.
    • Automation scripting in a simple, intuitive language allowing non-programmers to reduce operator error by automating repetitive steps.
    • Pop-Up Work Instructions. choose the exact amount of detail, imagery, language and automation you need to ensure your work instructions and tests are carried out flawlessly.
    • Flexible tolerancing: optionally define as percentages or absolute terms, as well as asymmetrically (e.g. +0%/-10%) for improved yields.
    • Barcode-tracking & archival data-logging to achieve error-proof test process and improved traceability & productivity.
    • Print PASS/FAIL labels, test reports (with or without color wiring schematics/netlists) and log reports to satisfy ISO9000 reporting requirements.
    • Compatible with laptop and touchscreen PCs for fieldwork and rack/off-bench mounting.
    Includes: CB29 board set (Item 759) for bare wire connections; comprehensive PC software with Database of >200 standard cables; 2 yr Product Support Subscription comprising Warranty, free tech support, and free software upgrades. Select Add-On Options: Hardware: 128-point Expansion Modules (attach to base); 4-Wire Kelvin Resistance Measurement, 1 mΩ at 1 A; Advanced Measurements; External Measurement Instrument Port (e.g. 10 GΩ Isolation at 100 V); Remote Control Connector for Deadman Switch; Environmental Sensor Software: PinMap™ fixture editor, Connector Designer™ connector editor, or Autobuild™ guided assembly modules camiresearch.com |@CAMI_CableEye |+1.978.266.2655

  • Outdoor Exposure Tester

    OET - PSE Instruments GmbH

    A comprehensive analysis of PV modules includes many different parameters. Determining the normal module operating temperature (NMOT), incidence angle effects and comparing soiling effects on different modules up to the initial degradation of PV modules are all parameters that can be analyzed with our outdoor exposure tester. The tester comes with up to twelve electronic loads installed in a 19" rack. The loads have two main functions: maximum power point tracking (MPPT) and IV curve tracing. For the advanced analysis, it is possible to change between these two modes within one test. In the normal operation mode, the electronic load keeps the module under MPP and each predefined interval an IV curve is traced. The entire tester comes with all necessary sensors such as temperature sensor, which can be attached to the module to determine the NMOT temperature like defined in IEC 61215 (MQT 05) and IEC 61853-2. The irradiation sensor is also included. In combination with our tracking system P2, it is also possible to determine incident angle effects of the PV module. It is also possible to connect other irradiation sensors for diffuse and direct irradiation, which helps to understand the behavior of the module in different irradiation conditions. An optional albedo meter is a powerful tool for the analysis of bifacial modules. The entire graphical user interface is web based and offers the possibility to access the system from the all computers in the network.

  • ARINC818 Cards

    AIM GmbH

    > ARINC818 is a specification which has become an Industry standard for the transmission of uncompressed digital video. This commercial standard uses Fibre Channel as a point-to-point communication link for low latency with the ARINC818 defining the packetized protocol for transmission of the digital video information. It is highly flexible and can be used for a variety of onboard display systems in both commercial and military applications. AIM’s ARINC818 cards use our field proven Common Core hardware design giving the best performance, best feature set and highest functional integration on the market. The use of SoC (System on Chip) based core designs with one dual core RISC processor per port, massive DDR3 memory and IRIG-B time encoder/decoder functions are standard. The ARINC818 modules are available in PCIe formats.The new ultra high performance intelligent 4-lane PCIe 2.0 interface modules offer 2 ports with full function test, simulation, monitoring and analyzer functions for ARINC818 interfaces. The dual core processor provides onboard processing and data transfer capabilities for the most demanding applications including ARINC818 support done on board level. Large and high data throughput DDR3 RAM is accessible for the onboard processor as is a high performance FPGA implementing the customized ARINC818 Interfaces enabling the board to analyze incoming data in real time. Each module provides 2 ARINC818 compliant ports. SFP cages make it suitable for different media types as optical or electrical network technologies. Each module is delivered with a Board Support Package (BSP) containing the onboard driver software, a full Application Programming Interface (API) and detailed getting started and programming guides. Powerful PBA.pro databus test and analysis software is optionally available for all our ARINC818 cards.

  • Phasing Voltmeter/Sensor (2 in 1)

    STB Electrical Test Equipment, Inc

    STB unit replaces 3 separate units manufactured by competitors - line phasing, capacitance phasing and line to ground Versatile, lightweight and easy to useEach portable meter has a single rangeMeter usage: Voltage detection and phasing at capacitance test points or voltage detection and phasing on bare energized conductors (overhead & underground)Probes can be separated to be used as a voltage sensor or capacitance sensorFive position selector switch used to select voltage sensing on capacitance tap or direct line and phasing on capacitance tap, direct line or a battery test positionNo exposed conducting terminals or meter circuitryLocking cable connector provides positive contactScale is large enough to be easily read 8'-10' when mounted on a suitable hot stickLine to ground voltage readings are accurate within 3% at full scaleMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)25' coiled cable includedAccessoriesMODELDESCRIPTION50118-G-10Hot Sticks (full set - 6)10104-P-02Shepherd's Hook10104-P-03Probe Tip30142-P-01Shot Gun Adapter50111-P-01Regular Bushing Adapter10275-P-01Universal AdapterModelsMODELDESCRIPTIONWeight50101-G-07Phasing Voltmeter 9-36kV16 lbs.50101-G-08Phasing Voltmeter 9-36kV with Hot Sticks (full set - 6)21 lbs.Request QuoteOperating Instructions9-36kV Phasing VoltmeterProduct Summary/OptionsProvides safe and convenient testing means for paralleling 3-phase high voltage circuitsConsists of two resistance elements connected in series with an indicating meter in the series connectionTwo ranges, 9kV and 36kV, with a range selector switch mounted on the back of the meter housingSwitch is clearly marked for the range of the voltmeterTypical use: Line-to-ground voltage measurements and phase for paralelling operationsScale markings on the voltmeter have a minimum of divisions and the figures are large enough to be easily read 8'-10' away when mounted on a suitable hot stickInput impedance: Approximately 72 megohmsMaximum operating temperature range -20°F to 165°F (-30°C to 75°C)Ready to attach on hot stick10' cable, a proof tester, battery and shepherd’s hook and probe tip includedOperating InstructionsRequest QuoteOperating InstructionsModelsMODELDESCRIPTION50100-G-010-2kV DC Voltmeter 30’ cable, magnetic track adapter50100-G-020-1500kV DC Voltage Meter50100-G-030-1500kV DC Voltage Meter with Hot Sticks50100-G-04DC Voltmeter 1500kV DC w/Extension Probe and Ground Lead50100-G-050-1500V DC with Hot Sticks and Lighted Dial50100-G-060-1500 DC Voltage Meter with Lighted DialDC Voltmeter​Product Summary/OptionsLightweight, easy to use, hand-held meterHard wired unit Scaled 0-1500vDC, in 100 volt incrementsProvides a 2/3 full scale deflection when applied across 1000vDCMaximum current flow through instrument at 1000vDC is 0.05 milliampersNo polarity, sensitivity issuesMay be used to determine whether the third rail of a transit system is energizedInput impedance of approximately 24 megohmMaximum operating temperature range -20°F to 165°F (-30° C to 75°C) Request QuoteAC VoltmeterProduct Summary/OptionsTwo-position toggle switchPortable instrument for quickly and easily measuring AC voltages Locking cable connector provides positive, electrical contactResistive voltmeter - medium range voltage measurements in the fieldTypical use - measure voltage between ground and the line or bus connector20' ground lead includedInput impedance - approximately 36 meghomsMaximum operating temperature rangeAccuracy of +/- 3% full scaleShare to TwitterShare to FacebookShare to PrintShare to EmailMore AddThis Share options